DESIGN AND DEVELOPMENT OF A STROKE REHABILITATION GLOVE FOR MEASURING AND MONITORING HAND MOTIONS

Authors

Keywords:

Paralysis, stroke, rehabilitation, assistive technology, flexion, extension, smart glove

Abstract

Muscular weakness tends to increase very rapidly due to various medical illnesses such as stroke, paralysis, fibromyalgia, etc. In order to keep tracks of the rehabilitative progress of patients who are suffering from such diseases, it is necessary to acquire data pertaining to finger movements including flexion and extension. Along with range of motions of proximal interphalangeal (PIP), distal interphalangeal (DIP) and meta-capo phalangeal joints, pinching strength is also vital in assessing the progress of rehabilitative therapies. Hence, our objective is to develop an assistive technology in the form of a smart glove comprising of flex and force sensors for measuring flexion and extension movements as well as the pinching strength. To the best of author’s knowledge, commercially available rehabilitation gloves are expensive and have some limitations such as being non-portable, having an antenna mount on the gloves facing upward and so on. The smart glove was able to measure the flexion and extension of finger movements and pinch strength with low-power requirements and low cost associated with production. The flexion and extension of finger movements along with pinching strength of stroke survivors was measured with the aid of the glove and showed promising outcomes. Through the results achieved by our developed glove, we were able to analyze the rehabilitative progress of stroke survivors. Moreover, the data is monitored continuously through liquid crystal display for rehabilitation purposes. Notably, this low cost glove was designed with the aid of flex sensors and force sensors that enabled the effective measurement of flexion, extension and pinching strength of stroke survivors.

References

H. Gates, L. S. Walters, J. Cowley, J. M. Wilken, and L. Resnik, “Range of motion requirements for upper-limb activities of daily living,” American Journal of Occupational Therapy, vol. 70, no. 1, pp. 7001350010p1-7001350010p10, 2016.

M. Pérez-Mármol et al., “Effectiveness of a fine motor skills rehabilitation program on upper limb disability, manual dexterity, pinch strength, range of fingers motion, performance in activities of daily living, functional independency, and general self-efficacy in hand osteoarthritis: A randomized clinical trial,” Journal of Hand Therapy, vol. 30, no. 3, pp. 262-273, 2017.

G. Behm, A. J. Blazevich, A. D. Kay, and M. McHugh, “Acute effects of muscle stretching on physical performance, range of motion, and injury incidence in healthy active individuals: a systematic review,” Applied physiology, nutrition, and metabolism, vol. 41, no. 1, pp. 1-11, 2016.

Tajika et al., “Relation between grip and pinch strength and pitch type in high school pitchers with and without elbow symptoms,” Journal of Orthopaedic Surgery, vol. 28, no. 1, p. 2309499019890743, 2020.

Kinney, D. M. Goodwin, and L. Gitlow, “Measuring Assistive Technology Outcomes: A User Centered Approach,” Assistive Technology Outcomes & Benefits (ATOB), vol. 10, no. 1, 2016.

J. Scherer, “Enhancing appropriate use of adaptive/assistive technology,” in Practical Psychology in Medical Rehabilitation: Springer, 2017, pp. 353-360.

C. Dewan et al., “Estimating the global incidence of traumatic brain injury,” Journal of neurosurgery, vol. 130, no. 4, pp. 1080-1097, 2018.

Langan, H. Subryan, I. Nwogu, and L. Cavuoto, “Reported use of technology in stroke rehabilitation by physical and occupational therapists,” Disability and Rehabilitation: Assistive Technology, vol. 13, no. 7, pp. 641-647, 2018.

Stephenson and J. Stephens, “An exploration of physiotherapists’ experiences of robotic therapy in upper limb rehabilitation within a stroke rehabilitation centre,” Disability and Rehabilitation: Assistive Technology, vol. 13, no. 3, pp. 245-252, 2018.

E. Dicianno et al., “The future of the provision process for mobility assistive technology: a survey of providers,” Disability and Rehabilitation: Assistive Technology, vol. 14, no. 4, pp. 338-345, 2019.

Carmeli, B. Imam, and J. Merrick, “Assistive technology and older adults,” in Health care for people with intellectual and developmental disabilities across the lifespan: Springer, 2016, pp. 1465-1471.

Sreejan and Y. S. Narayan, “A review on applications of flex sensors,” International Journal of Emerging Technology and Advanced Engineering, vol. 7, no. 7, pp. 97-100, 2017.

N. Farooq, M. A. M. Bandpei, M. Ali, and G. A. Khan, “Reliability of the universal goniometer for assessing active cervical range of motion in asymptomatic healthy persons,” Pakistan journal of medical sciences, vol. 32, no. 2, p. 457, 2016.

D. Hirschhorn, J. W. Lockhart, and J. D. Breckenridge, “Can a physical activity monitor provide a valid measure of arm elevation angle? A study to assess agreement between the SenseWear Mini Armband and the universal goniometer,” BMC musculoskeletal disorders, vol. 16, no. 1, pp. 1-9, 2015.

P. McHugh, A. M. Morton, B. Akhbari, J. Molino, and J. J. Crisco, “Accuracy of an electrogoniometer relative to optical motion tracking for quantifying wrist range of motion,” Journal of medical engineering & technology, vol. 44, no. 2, pp. 49-54, 2020.

C. Lim, M. Affandi, S. N. Basah, and M. Y. Din, “Evaluating lower limb joint flexion by computerized visual tracking system and compared with Electrogoniometer and universal goniometer,” Journal of Telecommunication, Electronic and Computer Engineering (JTEC), vol. 10, no. 1-4, pp. 9-14, 2018.

J. Otter et al., “The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion,” Journal of foot and ankle research, vol. 8, no. 1, pp. 1-7, 2015.

Taylor and K. Curran, “Glove-based technology in hand rehabilitation,” in Gamification: Concepts, Methodologies, Tools, and Applications: IGI Global, 2015, pp. 983-1002.

Devi and S. Deb, “Low cost tangible glove for translating sign gestures to speech and text in Hindi language,” in 2017 3rd International Conference on Computational Intelligence & Communication Technology (CICT), 2017: IEEE, pp. 1-5.

J. Wachter, M. Mentzel, C. Haederer, G. D. Krischak, and J. Guelke, “Change in the temporal coordination of the finger joints with ulnar nerve block during different power grips analyzed with a sensor glove,” Hand Surgery and Rehabilitation, vol. 37, no. 1, pp. 30-37, 2018.

da Cruz Teixeira and J. C. de Oliveira, “Right hand rehabilitation with cyberforce, cybergrasp, and cyberglove,” in 2015 XVII Symposium on Virtual and Augmented Reality (SVR), 2015: IEEE Computer Society, pp. 186-189.

Suarez-Escobar and E. Rendon-Velez, “An overview of robotic/mechanical devices for post-stroke thumb rehabilitation,” Disability and Rehabilitation: Assistive Technology, vol. 13, no. 7, pp. 683-703, 2018.

House et al., “Integrative rehabilitation of residents chronic post-stroke in skilled nursing facilities: the design and evaluation of the BrightArm Duo,” Disability and Rehabilitation: Assistive Technology, vol. 11, no. 8, pp. 683-694, 2016.

Lebleu, T. Gosseye, C. Detrembleur, P. Mahaudens, O. Cartiaux, and M. Penta, “Lower limb kinematics using inertial sensors during locomotion: accuracy and reproducibility of joint angle calculations with different sensor-to-segment calibrations,” Sensors, vol. 20, no. 3, p. 715, 2020.

Lebleu et al., “Lower limb kinematics improvement after genicular nerve blockade in patients with knee osteoarthritis: a milestone study using inertial sensors,” BMC Musculoskeletal Disorders, vol. 21, no. 1, pp. 1-12, 2020.

Rajkumar, F. Vulpi, S. R. Bethi, H. K. Wazir, P. Raghavan, and V. Kapila, “Wearable inertial sensors for range of motion assessment,” IEEE sensors journal, vol. 20, no. 7, pp. 3777-3787, 2019.

Downloads

Published

2022-07-07

How to Cite

DESIGN AND DEVELOPMENT OF A STROKE REHABILITATION GLOVE FOR MEASURING AND MONITORING HAND MOTIONS. (2022). Pakistan Journal of Rehabilitation, 11(2), 177-188. https://ojs.zu.edu.pk/pjr/article/view/1505